Chapter 9
Reject Tracking

9–4

Table 9.B
Discrete Bit Inputs (Excerpt From Table B.1, Part 3)

*PI Backplane

Remote I/O

*RS–232 ASCII

*RS–232 DFI

Word #

Bit #

Definition

Usage

Notes

0

0

Machine Stop

Condition

0 = No
Condition
1 = Condition

This bit indicates whether or not a
Machine Stop has occurred.

0

1

Configuration Error

0 = No Error
1 = Error

Configuration error bit is set after
any invalid configuration block write
to the Color CVIM. This flag is also
set after validation errors.

0

2

Mastership Flag

0 = Not Master
1 = Master

The device which reads this bit as 1
is the host. Not applicable for
RS–232 communications.

0

3

Module Busy

0 = Not Busy
1 = Busy

Module Busy bit is set during the
SETUP mode and while sending a
configuration download to the Color
CVIM.

0

4

Trigger

NAK

0 = OK
1 = Trigger
Missed

0

5

Post Results

0 = Part 1
1 = Part 2

0

6

Toolset

Data Valid

0 = Not Valid
1 = Results
Valid

Data Valid bit is reset when a user
enters the SETUP mode and when
pulsed output duration has expired.
Refer to Chapter 3.

0

7

Post Tracking

0 = No Tracking
1 = Tracking

This bit indicates whether or not
tracking data is present.

0

10–16

Machine Type

Value from 0 to
127 (decimal)

This is a 7–bit value.

0

17

Web Movement

0 = Horizontal
1 = Vertical

This is a 1–bit value.

1

0–7

Inspection Steps

Value from 0 to
255 (decimal)

This is an 8–bit value.

1

10–17

Bad–seal Steps

Value from 0 to
255 (decimal)

This is an 8–bit value.

2

0–7

Web–splice Steps

Value from 0 to
255 (decimal)

This is an 8–bit value.

2

10–17

Seal–splice Steps

Value from 0 to
255 (decimal)

This is an 8–bit value.

3

0–3

**Steps per field of

view

Value from 0 to
15 (decimal)

This is a 4–bit value.

3

4–7

**Lanes per field of

view

Value from 0 to
15 (decimal)

This is a 4–bit value.

3

10–17

Not used

0

All bits = 0.

4–7

All

Not used

0

All bits = 0.

*The reject tracking parameters are available only through the Remote I/O port.

**These values reflect the Web Movement parameter setting.