Chapter 8
Results and Outputs
8–9
You can control the results trigger from the
Envir/Cam
→
I/O
→
Results
Trig:
menu item. When you pick this menu item successively, it toggles
between
Results Trig: Disabled
and
Results Trig: Enabled
. The default
configuration is
Results Trig: Disabled
.
Important: The inspection trigger signal should be applied only while the
results trigger signal is low. Applying the inspection trigger
when the results trigger signal is high will lead to missed
inspections. Following an inspection, if a trigger occurs while
the results trigger input is high, the Color CVIM will assert the
Trigger NAK signal, and the trigger will not be processed.