Rockwell Automation 5370-CBPK Color CVIM BLISTER-PAK Option User Manual
Page 73
Chapter 9
Reject Tracking
9–3
Table 9.A
Discrete Bit Outputs (Excerpt From Table B.3)
*PI Backplane
Remote I/O
Word #
Bit #
Definition
Usage
Notes
0
16
Configuration Move
0 = No Request
1 = Request
Configuration Move commands are
specified in:
Output word 2 (Remote
I/O)
Output word 4
(Backplane)You must reset bit to 0, then
back to 1 to repeat a configuration move
request.
0
17
Not Used
1
0–7
Runtime Display Control
00000000 = No Change
00000001 = Display Image
Only
00000010 = Display Failed
Tools
00000100 = Display All
Tools
000010000 = Display I/O
Page
00010000 = Display Results
Page
00100000 = Display
Statistics
1 Page
01000000 = Display
Statistics
2 Page
1
10–17
Freeze On Reject
Control
00000000 = No Change
00000001 = Go On Reject
00000010 = Freeze First
Reject
00000100 = Freeze All
Rejects
00001000 = Freeze Next
Image
00010000 = Halt On Reject
2
0–3
Post Results to
Remote I/O Flag
0000 = Not Valid
0001 = Part 1
0010 = Part 2
0011 = Tracking
Post Results to Remote I/O Flag controls
which part of the results are assigned to
discrete input words 1 through 7.
Remote I/O only.
2
4–5
Discrete I/O Control
00 = No Change
01 = Disable Outputs
10 = Enable Outputs
Discrete and Forced I/O Control refer to
the local I/O module (Catalog No.
2801–JMB).
2
6–7
Forced I/O Control
00 = No Change
01 = Disable Forces
10 = Enable Forces
Forced I/O Control acts upon the bit map
you setup in words:
4 and 5 (Remote I/O)
6 and 7 (Backspace)
*The reject tracking parameters are available only through the Remote I/O port.