Rockwell Automation 5370-CBPK Color CVIM BLISTER-PAK Option User Manual

Page 73

Advertising
background image

Chapter 9
Reject Tracking

9–3

Table 9.A
Discrete Bit Outputs (Excerpt From Table B.3)

*PI Backplane

Remote I/O

Word #

Bit #

Definition

Usage

Notes

0

16

Configuration Move

0 = No Request
1 = Request

Configuration Move commands are
specified in:
Output word 2 (Remote
I/O)
Output word 4
(Backplane)You must reset bit to 0, then
back to 1 to repeat a configuration move
request.

0

17

Not Used

1

0–7

Runtime Display Control

00000000 = No Change
00000001 = Display Image

Only

00000010 = Display Failed

Tools

00000100 = Display All

Tools

000010000 = Display I/O

Page

00010000 = Display Results

Page

00100000 = Display

Statistics
1 Page

01000000 = Display

Statistics
2 Page

1

10–17

Freeze On Reject

Control

00000000 = No Change
00000001 = Go On Reject
00000010 = Freeze First

Reject

00000100 = Freeze All

Rejects

00001000 = Freeze Next

Image

00010000 = Halt On Reject

2

0–3

Post Results to

Remote I/O Flag

0000 = Not Valid
0001 = Part 1
0010 = Part 2
0011 = Tracking

Post Results to Remote I/O Flag controls
which part of the results are assigned to
discrete input words 1 through 7.
Remote I/O only.

2

4–5

Discrete I/O Control

00 = No Change
01 = Disable Outputs
10 = Enable Outputs

Discrete and Forced I/O Control refer to
the local I/O module (Catalog No.
2801–JMB).

2

6–7

Forced I/O Control

00 = No Change
01 = Disable Forces
10 = Enable Forces

Forced I/O Control acts upon the bit map
you setup in words:
4 and 5 (Remote I/O)
6 and 7 (Backspace)

*The reject tracking parameters are available only through the Remote I/O port.