All tools display – Rockwell Automation 5370-CBPK Color CVIM BLISTER-PAK Option User Manual
Page 59
Chapter 7
Runtime Options
7–2
When you click on
All Tools
, the tool graphics for “all tools” appears
onscreen, as illustrated by the example in Figure 7.3.
Figure 7.3
Example: All Tools Display
Table 7.A lists the status strings that can appear within the blister windows:
Table 7.A
Tool Error Status Codes
String
Explanatory Note
PASS
The blister passed all inspection criteria.
FOREIGN
The system has detected foreign material within the blister.
EMPTY
The system has detected a blister containing no tablets or capsules (no
pixels of the learned color(s)).
EXTRA
The system has detected a blister containing more than the expected
number of tablets or capsules.
COLOR
The system has detected a blister containing a tablet or capsule of a
color different than expected.
OVERSIZE
The system has detected a tablet or capsule that is larger than that
permitted by the area tolerance.
POSITION
The system has detected a tablet or capsule that is outside the position
tolerance.
UNDERSIZE
The system has detected a tablet or capsule that is smaller than that
permitted by the area tolerance, yet shaped correctly.
BROKEN
The system has detected a tablet or capsule that is smaller than that
permitted by the area tolerance, and shaped incorrectly.
SHAPE
The system has detected a tablet or capsule that is of an acceptable
area, but shaped incorrectly.
MISSING
Signifies that the system encountered one or more empty pockets within
an otherwise acceptable blister.