Chapter 7
Runtime Options

7–2

When you click on

All Tools

, the tool graphics for “all tools” appears

onscreen, as illustrated by the example in Figure 7.3.

Figure 7.3
Example: All Tools Display

Table 7.A lists the status strings that can appear within the blister windows:

Table 7.A
Tool Error Status Codes

String

Explanatory Note

PASS

The blister passed all inspection criteria.

FOREIGN

The system has detected foreign material within the blister.

EMPTY

The system has detected a blister containing no tablets or capsules (no
pixels of the learned color(s)).

EXTRA

The system has detected a blister containing more than the expected
number of tablets or capsules.

COLOR

The system has detected a blister containing a tablet or capsule of a
color different than expected.

OVERSIZE

The system has detected a tablet or capsule that is larger than that
permitted by the area tolerance.

POSITION

The system has detected a tablet or capsule that is outside the position
tolerance.

UNDERSIZE

The system has detected a tablet or capsule that is smaller than that
permitted by the area tolerance, yet shaped correctly.

BROKEN

The system has detected a tablet or capsule that is smaller than that
permitted by the area tolerance, and shaped incorrectly.

SHAPE

The system has detected a tablet or capsule that is of an acceptable
area, but shaped incorrectly.

MISSING

Signifies that the system encountered one or more empty pockets within
an otherwise acceptable blister.