Chapter 8
Results and Outputs
8–3
Win1.9
The WIN1.9 result is a special function of object verification that allows you
to conveniently access the error status codes of all enabled object verification
windows through a single result. The Color CVIM BLISTER-PAK software
applies a logical “OR” operation to the error status code from each active
window to derive this summary value. It is accessible to the MATH-PAK
option as:
WIN1.9
The calculation of the WIN1.9 result may best be illustrated by example.
Suppose you obtained results from an inspection of Windows 1 through 12 as
shown in Table 8.C. As the table shows, the decimal values are 5132, 2, 132,
136, 4, and 2. (Note that windows 6 and 7 each have two errors in this
example; thus, their “ORed” values are 132 and 136, respectively.)
When all of these values are “ORed” together, the WIN1.9 result value is
decimal 655, as shown at the bottom of the table.
Table 8.C
Example of WIN1.9 Result Calculation
Decimal
Binary Error Code
Window #
Status
Error
Code
512
256
128
64
32
16
8
4
2
1
1
Pass
0
0
0
0
0
0
0
0
0
0
0
2
Pass
0
0
0
0
0
0
0
0
0
0
0
3
Pass
0
0
0
0
0
0
0
0
0
0
0
4
Foreign
Missing
513
1
0
0
0
0
0
0
0
0
1
5
Empty
2
0
0
0
0
0
0
0
0
1
0
6
Extra
Broken
132
0
0
1
0
0
0
0
1
0
0
7
Color
Broken
136
0
0
1
0
0
0
1
0
0
0
8
Extra
4
0
0
0
0
0
0
0
1
0
0
9
Pass
0
0
0
0
0
0
0
0
0
0
0
10
Pass
0
0
0
0
0
0
0
0
0
0
0
11
Empty
2
0
0
0
0
0
0
0
0
1
0
12
Pass
0
0
0
0
0
0
0
0
0
0
0
This is the WIN1.9 “ORed” result: 655
512
0
128
0
0
0
8
4
2
1