Win1.9 – Rockwell Automation 5370-CBPK Color CVIM BLISTER-PAK Option User Manual

Page 64

Advertising
background image

Chapter 8
Results and Outputs

8–3

Win1.9

The WIN1.9 result is a special function of object verification that allows you
to conveniently access the error status codes of all enabled object verification
windows through a single result. The Color CVIM BLISTER-PAK software
applies a logical “OR” operation to the error status code from each active
window to derive this summary value. It is accessible to the MATH-PAK
option as:

WIN1.9

The calculation of the WIN1.9 result may best be illustrated by example.
Suppose you obtained results from an inspection of Windows 1 through 12 as
shown in Table 8.C. As the table shows, the decimal values are 5132, 2, 132,
136, 4, and 2. (Note that windows 6 and 7 each have two errors in this
example; thus, their “ORed” values are 132 and 136, respectively.)

When all of these values are “ORed” together, the WIN1.9 result value is
decimal 655, as shown at the bottom of the table.

Table 8.C
Example of WIN1.9 Result Calculation

Decimal

Binary Error Code

Window #

Status

Error
Code

512

256

128

64

32

16

8

4

2

1

1

Pass

0

0

0

0

0

0

0

0

0

0

0

2

Pass

0

0

0

0

0

0

0

0

0

0

0

3

Pass

0

0

0

0

0

0

0

0

0

0

0

4

Foreign
Missing

513

1

0

0

0

0

0

0

0

0

1

5

Empty

2

0

0

0

0

0

0

0

0

1

0

6

Extra

Broken

132

0

0

1

0

0

0

0

1

0

0

7

Color

Broken

136

0

0

1

0

0

0

1

0

0

0

8

Extra

4

0

0

0

0

0

0

0

1

0

0

9

Pass

0

0

0

0

0

0

0

0

0

0

0

10

Pass

0

0

0

0

0

0

0

0

0

0

0

11

Empty

2

0

0

0

0

0

0

0

0

1

0

12

Pass

0

0

0

0

0

0

0

0

0

0

0

This is the WIN1.9 “ORed” result: 655

512

0

128

0

0

0

8

4

2

1

Advertising