Fault page display panel – Rockwell Automation 5370-CBPK Color CVIM BLISTER-PAK Option User Manual

Page 61

Advertising
background image

Chapter 7
Runtime Options

7–4

The

Fault Page

in the BLISTER–PAK option replaces the

Stat2 Page

in

the Color CVIM.

Fault Page

indicates the locations of faults with “X”

figures. Prior to selecting this page, however, you must set the statistical
samples (

System Setup

Exit

Runtime Init.

Stat. Samples:

) to 1

or greater for any “X” figures to appear.

Figure 7.5 is an example that illustrates the

Fault Page

.

Figure 7.5
Example: Fault Page Display Panel for BLISTER–PAK Option

Note the “X” figures on and near capsules in the image. These denote the
locations of faults that the system has found. Where a fault is found
successively at the same location, the previous X’s at that location will move
slightly each time a new fault is found, thus creating a visual impression of
multiple faults at that location.

During any one sampling period, the system can only display X’s that pertain
to the 100 most recent faults. Thus, when more than 100 faults occur, the
earlier X’s are displaced by the later X’s. When an X appears on the display,
it will remain there for a number of subsequent inspections that is equal to
the

Stat. Samples:

setting. Thus, if the

Stat. Samples:

setting is 50, an

individual X will remain on the display for the 50 inspection cycles
following its initial appearance (unless it is displaced earlier because the 100
fault storage limit).

For additional information on using runtime options, please refer to the Color
CVIM User’s Reference Manual
(Cat. No. 5370-ND009).

Fault Page Display Panel