Chapter 5
Auto Setup

5–22

If an acquired image is not O.K., the message box contains a message such
as this:

Bad Blister. Must Reject.
5 of 35 images accepted.

If this message appears, you must pick

Reject

, since the other menu items

are inactive (shaded).

When the system completes the part–teaching operation, it will have
calculated new position, area, and shape tolerance values. If any calculated
tolerance is lower than the corresponding minimum tolerance setting in the

Configure

menu, the minimum setting will override the calculated tolerance.

Conversely, if any calculated tolerance is higher than the corresponding
minimum tolerance setting, the calculated tolerance will be used.

The auto setup process is completed at this point.