Step 1 - Identify Your Unit

1-1

C

HAPTER

1

Step 1 - Identify Your Unit

The VSM500™ integrated drive/motor is an AC drive integrally mounted with an
inverter duty motor. Each unit consists of a drive section and a motor section.

The drive section is a single- or three-phase input, three-phase output inverter
providing open loop V/Hz regulation. It houses the PC boards and the blower. The
motor section is a four-pole, three-phase induction motor.

The unit’s default setup suits a wide range of applications. Two rotary switches and a
10-position slide switch on the Regulator board are used to adjust the setup, if
required.

VSM500 units are identified by model number. This number appears on the shipping
label and on the unit’s nameplate. Table 1.1 shows the format of this number and what
it indicates.

Standard units, described in section 1.1, provide remote operator control. Local
operator control units, described in section 1.2, provide local (default) or remote (user
option) control.

Table 1.1 – Model Number Format

nn n a a n n n n

Horsepower
1 = 1 HP
2 = 2 HP
3 = 3 HP
5 = 5 HP
Frame
0 = 56
1 = 140
2 = 180
Regulator
X = CT / VT
Display
S = Standard
W = Operator Controls
Input Voltage
1 = 1-Phase, 115 VAC
2 = 3-Phase, 230 VAC
3 = 1-Phase, 230 VAC
4 = 3-Phase, 460 VAC
CE Certification
0 = Without Mains Filter
Enclosure Type
0 = Drive Section Only
1 = Standard
Mounting
1 = C-face and Foot

Advertising