Output voltage:
•
M/N __X_4_1_ 380 to 460 VAC, 3-phase
•
M/N __X_2_1_ 200 to 230 VAC, 3-phase
•
M/N __X_3_1_ 200 to 230 VAC, 3-phase
•
M/N __X_1_1_ 115 VAC, 3-phase
Maximum continuous output current:
Maximum output current:
Important: Maximum current ratings above are for the CT rating. When VT is
selected, the maximum output current will be limited to 110%.
Output frequency:
•
0 to 120 Hz
Carrier frequency:
•
8 kHz
M/N
Input Voltage
Unit HP
Output Current
(Motor Rated Amps)
1_X_4_1_
460 VAC
1 HP
1.7 A
2_X_4_1_
460 VAC
2 HP
3.2A
3_X_4_1_
460 VAC
3 HP
4.5 A
5_X_4_1_
460 VAC
5 HP
6.9 A
1_X_2_1_
230 VAC
1 HP
3.4 A
2_X_2_1_
230 VAC
2 HP
6.4 A
1_X_3_1_
230 VAC, 1-phase
1 HP
3.4 A
2_X_3_1_
230 VAC, 1-phase
2 HP
6.4 A
1_X_1_1_
115 VAC
1 HP
6.8 A
M/N
Input Voltage
Unit HP
Maximum Output
Current
(150% Rated Amps)
1_X_4_1_
460 VAC
1 HP
2.55 A
2_X_4_1_
460 VAC
2 HP
4.8 A
3_X_4_1_
460 VAC
3 HP
6.75 A
5_X_4_1_
460 VAC
5 HP
10.35 A
1_X_2_1_
230 VAC
1 HP
5.1 A
2_X_2_1_
230 VAC
2 HP
9.6 A
1_X_3_1_
230 VAC, 1-phase
1 HP
5.1 A
2_X_3_1_
230 VAC, 1-phase
2 HP
9.6 A
1_X_1_1_
115 VAC
1 HP
10.2 A