Output voltage:

M/N __X_4_1_ 380 to 460 VAC, 3-phase

M/N __X_2_1_ 200 to 230 VAC, 3-phase

M/N __X_3_1_ 200 to 230 VAC, 3-phase

M/N __X_1_1_ 115 VAC, 3-phase

Maximum continuous output current:

Maximum output current:

Important: Maximum current ratings above are for the CT rating. When VT is

selected, the maximum output current will be limited to 110%.

Output frequency:

0 to 120 Hz

Carrier frequency:

8 kHz

M/N

Input Voltage

Unit HP

Output Current

(Motor Rated Amps)

1_X_4_1_

460 VAC

1 HP

1.7 A

2_X_4_1_

460 VAC

2 HP

3.2A

3_X_4_1_

460 VAC

3 HP

4.5 A

5_X_4_1_

460 VAC

5 HP

6.9 A

1_X_2_1_

230 VAC

1 HP

3.4 A

2_X_2_1_

230 VAC

2 HP

6.4 A

1_X_3_1_

230 VAC, 1-phase

1 HP

3.4 A

2_X_3_1_

230 VAC, 1-phase

2 HP

6.4 A

1_X_1_1_

115 VAC

1 HP

6.8 A

M/N

Input Voltage

Unit HP

Maximum Output

Current

(150% Rated Amps)

1_X_4_1_

460 VAC

1 HP

2.55 A

2_X_4_1_

460 VAC

2 HP

4.8 A

3_X_4_1_

460 VAC

3 HP

6.75 A

5_X_4_1_

460 VAC

5 HP

10.35 A

1_X_2_1_

230 VAC

1 HP

5.1 A

2_X_2_1_

230 VAC

2 HP

9.6 A

1_X_3_1_

230 VAC, 1-phase

1 HP

5.1 A

2_X_3_1_

230 VAC, 1-phase

2 HP

9.6 A

1_X_1_1_

115 VAC

1 HP

10.2 A

Advertising