I/o specifications – Rockwell Automation VSM500 Integrated Drive/Motor User Manual

Page 79

Advertising
background image

Technical Specifications

A-5

Communication Fault (DeviceNet Option):

Trip on communication loss or malfunction

Motor thermal overload:

Trip time = 1 minute at 150% of rated current (CT)

Trip time = 1 minute at 110% of rated current (VT)

DC bus undervoltage:

I/O Specifications

Important: All signals are isolated from the incoming 3-phase power.

Analog inputs

0 to 10 V

Input impedance: 50 k

Resolution: 0.11%

4 to 20 mA

Input impedance: 250

Resolution: 0.14%

Analog output

0 to 10 V

Minimum load resistance: 2 k

Resolution: 0.4%

Logic inputs (Stop, Start, Reset, Fwd/Rev, RPM/%Load, Function Loss, Preset
Speed)

24 VDC sourcing inputs

Maximum input voltage: 28.8 VDC
Input current @ 24 VDC: 10 mA
Maximum OFF state voltage: 5 VDC
Minimum ON state voltage: 15 VDC

Relay output (1 form A N.O. contact) isolated

Maximum current (resistive or inductive): 1 A

Minimum current: 10 mA

Maximum voltage: 28 VDC, 250 VAC

Line Voltage

Trip Level

460 VAC

435 VDC

380 VAC

358 VDC

230 VAC

218 VDC

115 VAC

109 VDC