Step 7 - Wire the Control Signal Terminal Block

7-5

7.2

Wiring the Analog Output

The analog output provides a 0 to 10 VDC signal to a user-supplied metering device.
This output indicates speed (default) or %load (user option), based on the status of
input terminal 12.

If you select speed indication, 0 to 10 V = 0 to the maximum speed as defined by the
maximum speed rotary switch. (Refer to chapter 8 for a description of the rotary
switch.)

If you select %load indication, 0 to 10 V = 0 to 200% load.

Wire to the analog output as shown in figure 7.5.

Figure 7.5 – Analog Output Wiring

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Common

0 to 10V Output