Ppendix, Product features, B.1 new features in version 3.0 – Rockwell Automation VSM500 Integrated Drive/Motor User Manual

Page 81

Advertising
background image

Product Features

B-1

A

PPENDIX

B

Product Features

The following features are standard on every VSM500 unit:

Totally enclosed standard NEMA frame sizes with C-face and foot mounting. IEC
frames and flanges are available.

PWM (pulse-width modulated) drive section with a microprocessor-based V/Hz
regulator.

Design B inverter-duty motor section:

-

Class F non-hygroscopic insulation system resists heat, oil, and water.

-

Double-shielded bearings.

Four-character, seven-segment LED display to indicate speed, %load, and
diagnostic information.

0 to 10 VDC or 4 to 20 mA analog input for remote speed reference from a PLC or
process controller.

0 to 10 VDC analog output to provide remote speed or %load indication.

Seven selectable preset speeds.

Form A contact output to indicate drive running or drive faulted condition.

500 ms power dip ride-through time.

Protection features, including sensing for overtemperature, overcurrent, high DC
bus voltage, low DC bus voltage, and surge suppression.

Conduit cover can be rotated 180

°

to provide the appropriate display view in each

application.

User-selectable coast-to-rest (default) or ramp-to-rest (user option) stop.

User-selectable variable torque (default) or constant torque (user option) operation.

8 kHz carrier frequency for quiet operation.

Complies with UL 1995.

B.1 New Features in Version 3.0

Additional start mode selection. Local operator control units can be controlled
from either the operator controls or the terminal block.

Terminal block stop input. The terminal block stop input and local operator control
stop key are active for all start mode selections.

Zero speed operation. The minimum speed has been reduced from 90 RPM (3 Hz)
to zero.

Advertising