Step 1 - Identify Your Unit

1-5

1.2.5 Operating the Unit Using the Local Operator Controls

Important: If the local operator controls are disconnected from or connected to the

unit after power up, the unit will stop due to a non-resettable fault. Refer to
chapter 11 for information about faults.

1.3

Option Kits

Table 1.2 lists the VSM500 option kits.

Desired Action

User Steps

Start the unit.

1

1

If the unit is set up for terminal block control (see section 8.3.9), the

and

keys are not

functional.

Press the green

key.

Stop the unit.

Press the red

key.

Change the direction of motor rotation.

1

Press the

key.

Clear faults.

Press the

key.

Decrease the speed reference.

2

2

If the unit is using a preset speed reference (see section 7.4.1) or terminal block speed reference (see

section 8.3.2), pressing the

or

key will have no effect on unit operation.

Press the

key until the speed reference displayed is the desired value. The

longer the

key is held down, the faster the value decreases.

Display the current speed
reference

Press the

or

key once.

The display returns to indicating speed in RPM or %load after three to five
seconds. (Note that holding down either key will change the speed reference.)

Display the speed in RPM

No action required; speed in RPM is the default display based on status of
terminal 12 (see section 7.4).

If the

or

keys are not pressed for several seconds, the display returns

to indicating actual motor speed in RPM.

Display %load

Close contact on terminal 12 (see section 7.4)

Increase the speed reference.

2

Press the

key until the speed reference displayed is the desired value. The

longer the

key is held down, the faster the value increases.

Cancel Auto Restart sequence.

Press the

key.

RESET

RESET

Table 1.2 – VSM500 Option Kits

Drive Input Rating

CE Filter Option Kit

DeviceNet

Communication

Option Kit

Internal Mount

External Mount

115V, 230V
Single Phase

VSM-CE-1I

VSM-CE-1E

DNVSM500

230V, 460V
Three Phase

VSM-CE-3I

VSM-CE-3E