Installing and Operating the VSM500 Integrated Drive/Motor, Version 3.0

Nominal power dissipation for motor and drive combined:

Weight:

Shock:

15 G Operational, 30 G Non-Operational

Vibration:

1.0 G Operational, 2.5 G Non-Operational

Drive Protection/Fault Detection

Output overcurrent:

Trip level = 200% of max peak rated current

Output ground fault:

Trip level = 200% of max peak rated current DC bus overvoltage:

Input Voltage

Unit HP

Nominal Watts Loss

460 VAC

1 HP

150 W

460 VAC

2 HP

250 W

460 VAC

3 HP

350 W

460 VAC

5 HP

550 W

230 VAC

1 HP

150 W

230 VAC

2 HP

250 W

230 VAC, 1-phase

1 HP

150 W

230 VAC, 1-phase

2 HP

260 W

115 VAC, 1-phase

1 HP

180 W

Input Voltage

Unit HP

Weight

460 VAC

1 HP

38 lb

460 VAC

2 HP

49 lb

460 VAC

3 HP

59 lb

460 VAC

5 HP

59 lb

230 VAC

1 HP

38 lb

230 VAC

2 HP

49 lb

230 VAC, 1-phase

1 HP

38 lb

230 VAC, 1-phase

2 HP

49 lb

115 VAC, 1-phase

1 HP

38 lb

Line Voltage

Trip Level

460 VAC

830 VDC

230 VAC

415 VDC

115 VAC

208 VDC