Rockwell Automation VSM500 Integrated Drive/Motor User Manual
Page 78
![background image](/manuals/580889/78/background.png)
A-4
Installing and Operating the VSM500 Integrated Drive/Motor, Version 3.0
Nominal power dissipation for motor and drive combined:
Weight:
Shock:
•
15 G Operational, 30 G Non-Operational
Vibration:
•
1.0 G Operational, 2.5 G Non-Operational
Drive Protection/Fault Detection
Output overcurrent:
•
Trip level = 200% of max peak rated current
Output ground fault:
•
Trip level = 200% of max peak rated current DC bus overvoltage:
Input Voltage
Unit HP
Nominal Watts Loss
460 VAC
1 HP
150 W
460 VAC
2 HP
250 W
460 VAC
3 HP
350 W
460 VAC
5 HP
550 W
230 VAC
1 HP
150 W
230 VAC
2 HP
250 W
230 VAC, 1-phase
1 HP
150 W
230 VAC, 1-phase
2 HP
260 W
115 VAC, 1-phase
1 HP
180 W
Input Voltage
Unit HP
Weight
460 VAC
1 HP
38 lb
460 VAC
2 HP
49 lb
460 VAC
3 HP
59 lb
460 VAC
5 HP
59 lb
230 VAC
1 HP
38 lb
230 VAC
2 HP
49 lb
230 VAC, 1-phase
1 HP
38 lb
230 VAC, 1-phase
2 HP
49 lb
115 VAC, 1-phase
1 HP
38 lb
Line Voltage
Trip Level
460 VAC
830 VDC
230 VAC
415 VDC
115 VAC
208 VDC