Step 9 - Check the Installation

9-3

9.3.1 Rotating the Cover

Before rotating the cover, take the following precautions:

Step 1. Turn off, lockout, and tag AC input power to the drive.

Step 2. Remove the cover by loosening the four cover screws. Note that the display

board ribbon cable is designed to disconnect when the cover is removed.

Step 3. Wait five minutes after disconnecting power and verify that DC bus voltage is

zero. See figure 5.1 for the location of the DC bus test points.

Refer to figure 9.2 and use the following procedure to rotate the cover:

Step 1. Remove the display board ribbon cable from the display board. You will need

to insert a small screwdriver into the cable latch to release it from the board.

Step 2. Insert the display board ribbon cable into the opposite side of the display

board. Push the cable in until it clicks. Verify the connection by lightly tugging
on the cable.

Step 3. Rotate the cover.

Step 4. Connect the display board ribbon cable together.

Step 5. Position the cover and tighten the four cover screws. The tightening torque

limit for the cover screws is 1.3 to 1.7 Nm (11 to 15 in-lb). Verify that all four
screws are securely tightened before applying power.

Figure 9.2 – Rotating the Cover

Cover Screws (4)

Display Board

Ribbon Cable Connector

Advertising