macros in the application. If a new user logs in before the previous user has logged
out, the logout macro of the previous user runs after the new user logs in.

A-P Security Codes. For a new user, all the boxes are selected by default (Y is
shown in all columns in the spreadsheet). To block access to a security code, clear

the check box for the code in the form section.

To remove a FactoryTalk Security user or group from FactoryTalk
View
1. Open the Runtime Security editor and select the ME Runtime 4.00 and later tab.

2. In the Account column, select a user or group, and click Remove.

3. Click Yes.

To migrate RSView 3.20 and earlier users to FactoryTalk View

1. With the Runtime Security editor open and the ME Runtime 4.00 and later tab

selected, from the Setup menu, select Migrate ME Runtime 3.20 and earlier
accounts
.

Users from the ME Runtime 3.20 and earlier tab are added to the FactoryTalk
Security Users folder and to the ME Runtime 4.00 and later tab.

2. If desired, edit the users’ security codes and login and logout macros.

3. To edit the users’ passwords, see page 11-26.

Be sure the DEFAULT user is allowed at least one security code, and assign the same security
code (or the * code) to the initial graphic display. If the DEFAULT user has no security codes
allowed, when the application is run, no display will open.

Users are not migrated if they already exist in the ME Runtime 4.00 and later
account list.