16

Transfer applications to a PanelView Plus terminal

16-3

• •

Install printers on a PanelView Plus 7 or PanelView Plus 6
terminal

If you will be printing displays, alarms, reports, or diagnostics messages, connect a
printer to the USB or Network port.

PanelView Plus 7 and PanelView Plus 6 terminals incorporates the JETCET PRINT
solution for Microsoft Windows CE devices, supporting select Canon, Epson,
Hewlett-Packard, and Brother printers. Plug-and-play installation is supported for
these printers as well as manual installation if a suitable JETCET print driver is
available.

Print support is centrally managed and independent of the application. You can add
and configure a new printer from the desktop control panel. Printer configurations
include the printer name, printer driver, port, and port-specific parameters. New
configurations are retained through a power cycle.

Transfer applications

1. On the PanelView Plus 7, PanelView Plus 6, PanelView Plus, or PanelView Plus CE

terminal, start FactoryTalk View ME Station.

For more information, see page 16-4.

2. In FactoryTalk View ME Station, if you’re transferring via a serial connection, specify

and set up the serial driver. If you are using Ethernet for the transfer, you can skip this
step.

For more information, see page 16-4.

3. On the development computer, set up the RSLinx Enterprise driver to use for the

transfer.

For more information, see page 16-6.

4. Move the application to the PanelView Plus 7, PanelView Plus 6, or PanelView Plus

terminal using the Transfer Utility tool.

For more information, see page 16-6.

You can also transfer applications to the terminal using a Flash Card. For information
about this method, see the PanelView Plus Terminals User Manual.