Convert PanelBuilder and PanelBuilder32 applications

B-5

• •

Conversion messages are saved in a file called Convert.log, in the HMI projects directory.

To convert a PanelBuilder application when FactoryTalk View
Studio is already open

1. From the File menu, select New Application, or click the New Application tool.

If an application is already open, FactoryTalk View Studio asks you whether to close
the application that is currently open. Click Yes.

2. Follow steps 2 through 7 in the previous procedure.

Equivalent graphic objects

This section describes graphic objects that are equivalent in PanelBuilder and FactoryTalk
View, but have different names in the two products.

This PanelBuilder object

Is converted to this FactoryTalk View
object

Notes

Numeric Entry Keypad Enable
Button

Numeric input enable button

Numeric Entry Cursor Point

Numeric input enable button

Increment/Decrement Entry Button

Numeric input enable button

The Numeric Input Enable button is set
up to work as a Ramp button, using the
Fine Step value. The Coarse Step value is
not converted.

ASCII Entry Keypad Enable button

String Input Enable button

The Show Current String on ASCII
Scratchpad setting is not converted. The
pop-up scratchpad or keyboard is always
blank when opened.

ASCII Entry Cursor Point

String Input Enable button

The Show Current String on ASCII
Scratchpad setting is not converted. The
pop-up scratchpad or keyboard is always
blank when opened.

Message Display

Multistate indicator

Numeric Data Display

Text

The text object contains a numeric
embedded variable that shows the read
tag.

If the original numeric data display object
does not contain text, manually create a
numeric display object with the desired
properties in FactoryTalk View.