information message display you have created, or can be placed in any display in your
application.

For information about setting up the information message display graphic object, see
page 21-65.

What is shown

If the Value connection is unassigned, the information message graphic display never
opens automatically. If the operator opens a graphic display containing an information
message display object, the object is blank.

The Value connection is rounded up to the nearest integer. If the value does not match
any of the trigger values in the specified message file, the display is filled with
question marks (?).

For information about how values are rounded, see page 7-2.

If the message is too long to fit in the information message display object, the last
shown character is replaced with an asterisk (*).

When the Value connection’s value is 0, the information message graphic display is
closed.

If you set up information messages in multiple languages, messages are shown in the
current application language. When a language switch occurs, a message that was
already in the information message display remains in the language that it originally
appeared in. New messages are shown in the new language.

Change the message file used at run time

Your application can use only one message file at a time. Follow this procedure to switch
message files.

1. Shut down the application.

2. Start FactoryTalk View Studio and open the application.

3. In the Information Setup editor, specify the new information message file.

4. Create the run-time application. See Chapter 14.

5. Transfer the run-time application to the run-time platform.

For information about transferring applications to:

A personal computer, see Chapter 15.

A PanelView Plus or PanelView Plus CE terminal, see Chapter 16.

6. Run the new application.