16

Transfer applications to a PanelView Plus terminal

16-7

• •

To start the Transfer Utility tool

On the development computer, do one of the following:

In FactoryTalk View Studio, from the Tools menu, select Transfer Utility.

From the Windows Start menu, select Programs > Rockwell Software >
FactoryTalk View > Tools
, and then click ME Transfer Utility.

For details about using the utility, see the utility’s Help.

Upload applications from the PanelView Plus 7, PanelView Plus
6, PanelView Plus, or PanelView Plus CE terminal

Use the Transfer Utility to upload your run-time application from the PanelView Plus 7,
PanelView Plus 6, PanelView Plus, or PanelView Plus CE terminal to the development
computer. Run-time applications have the extension .mer.

Any password changes that were made while the application was running are saved in the
.mer file and will be uploaded.

If the upload process fails or is cancelled, the application file will be deleted from the destination
directory. Make sure there is enough storage space on the destination computer.