Install Microsoft SQL Server 2005 Express

• •
• •

189

Step 4: Install Microsoft SQL Server Management Studio Express

Use Microsoft SQL Server Management Studio Express to perform management
operations on the alarms and events database, such as adding or removing users.

To install Microsoft SQL Server Management Studio Express:

1. Close any programs that are open.

2. At the root of the FactoryTalk View Site Edition or RSLinx Enterprise CD, open

the Redist folder, open the SQLServer2005 folder, and then double-click
SQLServer2005_SSMSEE.msi.

3. In the Welcome window, click Next.

4. Review the End User License Agreement, select the option to accept it, and then

click Next.

5. In the Registration Information window, enter the required information, and

then click Next.

6. In the Feature Selection window, click Next.

7. Click Install to begin the installation.

8. When the installation is finished, click Finish to close the window.

Error message

During the installation of Microsoft SQL Server Management Studio Express or while
the program is running, the following error message might appear:

The file C:\WINDOWMicrosoft.NET\Framework\

\mscorlib.tlb could not be

loaded. An attempt to repair this condition failed because the file could not be found.

If you see this error message, there is a problem with a registry key. To correct the
problem, follow the instructions at the Microsoft web site:

http://support.microsoft.com/?kbid=918685

.