Rockwell Automation 2098 CompactLogix Indexing Motion Accelerator Toolkit Quick Start User Manual

Page 78

Advertising
background image

78

Publication IASIMP-QS011B-EN-P — January 2009

Chapter 6

Motion FactoryTalk View Integration

Edit Axis Shortcuts

In this example, AXIS_01 is renamed CONVEYOR and GenericMachine_COND is renamed
SorterMachine_COND to match the changes in our Logix application in

Chapter 5

Motion Logix

Integration.

1. In FactoryTalk View ME software, expand the Explorer window to gain access to Parameters.

If needed, refer to

Add the Parameter File

on

page 72

to see how that was done.

2. Double-click the Axis 1 Status file.

3. Rename the #2 and the #4 shortcut to match the axis and machine names used in your

RSLogix 5000 program file.

4. Repeat step 2…step 3 for each axis to rename the shortcuts.

Edit Axis Display Names

Follow these steps to provide meaningful names to the axes as they are displayed on the operator
interface. You will change the Initial Value field for the HMI tags. In this example, Axis 1 is
renamed Conveyor.

1. In FactoryTalk View ME software, expand the Explorer window to gain access to HMI tags.

If needed, refer to

Add an HMI Tag

on

page 74

to see how that was done.

2. Rename the Initial Value field to match the axis name used in your RSLogix 5000 program file.

IMPORTANT

Follow these steps to rename the axes in your FactoryTalk View ME program if you changed the
names of the axes in your CompactLogix application file.

Advertising