Rockwell Automation GV3000/SE Operator Interface Module (OIM) User Guide User Manual
Page 16
 
2-4
GV3000/SE Operator Interface Module (OIM) User Guide, Version 2.0
Program or 
Monitor
When the control source is set to OIM, jogs the motor when held down (and the 
drive is ready). The motor ramp stops when it is released.
When
is pressed, the motor ramps up to the JOG SPEED REFERENCE
(P.020) at the speed set by JOG RAMP ACCEL TIME (P.021). When it is 
released, the drive ramps down to zero at the speed set by JOG RAMP DECEL 
TIME (P.022). 
Program or 
Monitor
When the control source is set to OIM, applies power to the motor.
is
only active if the drive ready indicator is on.
Program or 
Monitor
If the drive is running, the drive is stopped as selected by STOP TYPE (P.025).
When the OIM is connected and communicating with the drive,
is active,
regardless of the control source.
If the drive is not running and the control source is set to OIM,
resets any
active faults. See chapter 7 for more information on resetting faults.
Refer to the P.055 (STOP/RESET Key Disable) parameter description in the
software I/M for more information about
.
Table 2.2 – Control Key Descriptions (Continued)
Key
Mode
Function
!
ATTENTION: Pressing
on the OIM immediately starts the
motor if the control source is set to OIM. Make sure the motor and 
driven machinery are safe to start before pressing this key. Failure 
to observe this precaution could result in severe bodily injury or 
loss of life.
!
ATTENTION: Pressing
on the OIM immediately starts the
motor if the control source is set to OIM. Make sure the motor and 
driven machinery are safe to start before pressing this key. Failure 
to observe this precaution could result in severe bodily injury or 
loss of life.
!
ATTENTION: When P.055 is set to ON,
is functional only from
the selected control source. As a safety precaution, Reliance 
Electric recommends that an emergency stop push button be 
located near the drive in an easily accessible location. As a further 
safety precaution, the user should post a warning on the drive to 
alert personnel that 
is not functional. Failure to observe this
precaution could result in severe bodily injury or loss of life.
ATTENTION: The user must provide an external, hardwired 
emergency stop circuit outside the drive circuitry. This circuit must 
disable the system in case of improper operation or OIM failure. 
Uncontrolled machine operation can result if the procedure is not 
followed. Failure to observe this precaution could result in bodily 
injury.