Rockwell Automation GV3000/SE Operator Interface Module (OIM) User Guide User Manual

Page 30

Advertising
background image

3-10

GV3000/SE Operator Interface Module (OIM) User Guide, Version 2.0

Using the example of a full scale value of 500.0 and MOTOR TOP SPEED of
1750, the OIM would convert the speed units as follows:

Note that normalized values in the drive remain at 1 count in 4095 regardless
of the full scale value setting.

Step 4. To set the full scale value, move the cursor (

) to the number or the sign

that needs to change. (You will set the decimal point in step 5.) Press

or

to change the number. Press

to move between the numbers.

Press

when the constant is correct.

For full scale values less than 2000, you can set one decimal place. For full
scale values less than 200, you can set up to two decimal places.

If the full scale value you set allows decimal places, the decimal place screen
is displayed, as shown in figure 3.8. Continue to step 5.

If the value you set does not allow a decimal place, go to step 6.

Step 5. Press

to move the cursor (

) to the number of decimal places you want.

Press .

Step 6. Speed units programming is complete and you are returned to the menu.

Actual Speed

(RPM)

Conversion

Displayed Value

(ft/min)

1750

1750 * 500.0

1750

500.0

875

875 * 500.0

1750

250.0

-350

-350 * 500.0

1750

-100.0

0

0 * 500.0

1750

0.0

Figure 3.8 – Define Speed Units Screen