OPERATOR’S MANUAL

AI-120 Virtual Terminal

11001-1606B-201310

TERMINAL SETUP / 69

ECU SETTINGS (SYSTEM REFRESH)

ECU settings are normally set when creating a new implement. However,
adjustments to ECU settings can be required after initial setup as follows:

Implement changes require a refresh of the terminal to synchronize
with ECU settings for the following implement changes:
– IntelliAg WSMT PDC system: Row width settings and/or clutch

configuration settings are modified

– AI-120 terminal: When the implement control type or the implement

function on the ECU Setup screen is modified.

– When changing from a variable rate job to a manual as applied rate

job.

Loading a software update to modules connected to the CAN Bus

To Adjust Implement Settings:

1. At the Setup screen, press the Implement/ECU icon.
2. Selecting and changing an implement control or function at this screen

automatically prompts a system refresh.

3. Press the Check button to return to the main screen.

To Adjust Implement Function:

4. Press the Implement Function button to identify the implement type

as:
– Sprayer
– Spreader
– Planter

NOTE:

The terminal must be receiving
a GPS signal for the auto
section control to update
correct section widths.

Figure 103

Refresh ECU Settings