80 / AUTO SECTION CONTROL SETUP

NOTE:

On Time and Off Time only
applies to systems that use
output modules and switch
modules and does not apply to
Section Control by Channel.

– On Time establishes when actual product application starts after

the sections are switched on.

– Off Time establishes when actual product application stops after

the sections are switched off. Off time cannot exceed the On time
setting.

Delay times vary based on manufacturer. Refer to (

Figure 112

) for

recommended clutch delay times.

Delay time defaults for both turning on and shutting off is set at 0.0 seconds.

IMPORTANT: The shutoff delay time is a mechanical delay for

engaging and disengaging clutches. Seconds entered
at this screen will increase the look-ahead time when
shutting off and turning on rows controlled at the Auto
Section Control screens. Shutoff delay times can effect
accuracy of Run in and Run Out functionality.

Figure 112

Clutch Delay Times

Enter Timing:

1. At the Setup menu, press the Implement/Section Control/Timing icons

to display timing selections.

2. Press the On Time button and use the keypad to enter desired time to

start application.

3. Press the Check button to accept.
4. Press the Off Time button and use the keypad to enter desired time to

stop application

5. Press the Check button to accept.

Figure 113

On Time/Off Time

Clutch Type

Turn Off

Turn On

TruCount

0.4 seconds

0.4 seconds

Great Plains Electric Clutch

0.3 seconds

0.4 seconds