Operator’s manual – Great Plains DICKEY-john AI-120 12-inch Virtual Terminal User Manual
Page 84
OPERATOR’S MANUAL
AI-120 Virtual Terminal
11001-1606B-201310
76 / AUTO SECTION CONTROL SETUP
The Clutch Module Configuration screens displays:
•
Module address
•
Type
•
Number of outputs per module
To enter # of Outputs per Module:
1. At the IntelliAg Main Work screen, press the Module Configuration
button.
2. At the Module Configuration screen, press the Clutch Module button.
3. Enter the number of solenoid outputs connected to the specific TCOM.
Outputs do NOT always total the number of clutches but the total
number of controlled solenoids. The Output Numbers (#s) value is
automatically sequenced for each module based on the module
address value.
Figure 107
Clutch Configuration Screen
ASSIGNING ROWS
The Clutch Configuration screen assigns rows to outputs. As rows are
assigned to each output, row numbers automatically populate.
1. At the Clutch Module screen, press the Clutch Configuration button.
Enter number of rows to be assigned to each output.