AUTO SECTION CONTROL SETUP

Auto Section Control can be controlled through either the:

IntelliAg (individual row shutoff)
– requires planter output modules
– row shutoff module switches

AI-120 terminal (channel shutoff)
– row shutoff without connected output modules and switches

Auto section control is selected based on if this function is desired by row or
by channel. Setup and performance is different for each method.

INDIVIDUAL ROW SHUTOFF

Controlling sections by rows require:

Planter output modules

Row shutoff module switches

Setup is performed at the IntelliAg screens

IMPORTANT: IntelliAg settings should be entered first before entry of

AI-120 values so that number of sections, width, and
switch assignment is automatically populated into the
AI-120 terminal.

INTELLIAG PDC SETUP

The following IntelliAg PDC screens must be configured to perform Auto
Section Control functions via the AI-120 terminal.

Control channel setup assigning number of rows per channel

Clutch Module/Switch Assignment

Refer to the IntelliAg operator’s manual for setup instructions.

CLUTCH CONFIGURATION

Clutch configuration is required to:

Identify how many planter output modules are connected to the
IntelliAg system

Assign how many outputs are assigned to each output module

Assign how many rows are assigned to each output

Assign row shutoff module switches to outputs that enable and disable
planter sections

Multiple Tru Count Output Module Assignment

Output module addresses are a critical parameter used to identify a
module’s position on the implement that controls row shutoff switches.

IMPORTANT: If a planter uses more than one output module, modules

MUST be installed in increasing serial number order
starting on the left side and proceeding to the right so
that row assignment is configured correctly.