SECTION CONTROL SHUTOFF BY CHANNEL

Section control shutoff by channel is an optional feature to shutoff rows
when there are no output or switch modules connected to the system. Rows
are shutoff based on the number of rows assigned to a channel when
approaching a previously applied area.

To enable Section Control by Channel:

1. At the Setup menu, verify that ‘Auto Section Control’ is enabled

(System, Features, Implement).

2. Verify that either ‘Section Control Only’ or ‘Section Control and Rate

Control’ is selected at the ECU Setup menu (Implement, ECU,
Implement Control)
– Section Control by Channel is disabled by selecting Rate Control

only.

3. At the Main Menu, open the Auto Section Control window and select to

turn off channels by:
– Avoiding gaps--turns off the channel when the last row assigned to

the channel crosses the previously planted area causing overlap.

– Avoiding overlaps--turns off the channel when the first row

assigned to the channel crosses the previously planted area