Set storage array learn cycle, Set storage array time – Dell PowerVault MD3000 User Manual

Page 197

Advertising
background image

Script Commands

197

Set Storage Array Learn Cycle

This command sets the learn cycle for the battery backup unit, which enables
the MD Storage Manager Software to predict the remaining battery life.
Learn cycles run at set intervals, and they store the results for software
analysis.

Syntax

set storageArray learnCycleDate

(daysToNextLearnCycle=

integer-literal

| day=

string-literal

) time=

HH:MM

Parameters

NOTE:

You can set the learn cycle to occur only once during a seven-day period.

The time parameter selects a specific time that you want to run the learn cycle. If a
value is not entered, the command uses a default value of 00:00 (midnight). If the
day and time specified are in the past, the next learn cycle takes place on the next
possible day specified.

Set Storage Array Time

This command sets the clocks on both RAID controller modules in a storage
array by synchronizing the RAID controller module clocks with the clock of
the host from which you issue this command.

Parameter

Description

daysToNextLearnCycle Valid values are 0 through 7, where 0 is immediately and 7

is in seven days. The daysToNextLearnCycle parameter
takes place up to seven days after the next scheduled learn
cycle

day

Valid values include the days of the week (Sunday, Monday,
Tuesday, Wednesday, Thursday, Friday, and Saturday).
Setting the day causes the next learn cycle to be scheduled
on the specified day, after the currently scheduled learn
cycle.

time

The time in 24-hour format; for example 8:00 a.m. is
entered as 08:00. Nine o’clock p.m. is entered as 21:00, and
9:30 p.m. is entered as 21:30.