93

The script command set provides two commands to define media scan
properties:

set virtualDisks

set storageArray
The set virtualDisk command enables a media scan for the virtual disk.
The following syntax is the general form of the command:

set (allVirtualDisks | virtualDisk

[

virtualDiskName

] | virtualDisks [

virtualDiskName1

... virtualDiskNamen

] | virtualDisk <

wwid

>)

mediaScanEnabled=(TRUE | FALSE)

The set storageArray command defines how frequently a media scan is
run on a storage array. The following syntax is the general form of the
command:

set storageArray mediaScanRate=(disabled | 1-30)

Running a Consistency Check

Consistency checks are performed when media scans are run, if consistency
check is enabled on the virtual disk. (See "Running a Media Scan" on page 91
for an explanation about setting up and running media scans.) During a
consistency check, all data blocks in a virtual disk are scanned, and deteriorated
data is corrected. The method of correction depends on the redundant array of
independent disks (RAID) levels:

RAID 5 and RAID 6 virtual disks — Consistency is checked and repaired.

RAID 1 virtual disks — The data is compared between the mirrored
physical disks, and data inconsistencies are repaired.

RAID 0 virtual disks — No redundancy exists.

Before attempting a consistency check, you must enable the process with the
set virtualDisk command, which uses the following general form:

set (allVirtualDisks | virtualDisk

[

virtualDiskName

] | virtualDisks [

virtualDiskName1

... virtualDiskNamen

] | virtualDisk <

wwid

>)

consistencyCheckEnabled=(TRUE | FALSE)

Advertising