Script Commands

201

owner

Specifies the RAID controller module that owns the
virtual disk. Valid RAID controller module identifiers
are 0 or 1, where 0 is the RAID controller module on
the left and 1 is the RAID controller module on the
right when viewed from the rear of the enclosure. Use
only if you want to change the virtual disk owner.

writeCacheEnabled

Turns the write cache on or off. To turn on the write
cache, set this parameter to TRUE. To turn off the
write cache, set this parameter to FALSE. The default
value is TRUE.

cacheReadPrefetch

This parameter turns the cache read prefetch on or off.
To turn off cache read prefetch, set this parameter to
FALSE. To turn on cache read prefetch, set this
parameter to TRUE. The default value is TRUE.

addCapacity

Increases storage size (capacity) of the virtual disk for
which you are defining properties. Size is defined in
units of bytes, kilobytes, megabytes, or gigabytes, or
terabytes. The default units are bytes.
Virtual Disk capacity expansion increases the size of
the logical unit that is exposed by the RAID controller.
Refer to your OS documentation for additional
information about how the OS can recognize the
additional capacity on the virtual disk and increase the
size of OS volumes on the virtual disk.

addPhysicalDisks

Adds new physical disks to the virtual disk. Specify the
enclosure ID and slot ID for each physical disk that
you assign to the virtual disk. Enclosure ID values are 0
to 99. Slot ID values are 0 to 31. You must put brackets
([ ]) around the enclosure ID values and the slot ID
values. Use with the addCapacity parameter if you
must specify additional physical disks to accommodate
the new size.

consistencyCheckEnabled

Turns consistency checking during a media scan on or
off. To turn consistency checking on, set to TRUE. To
turn consistency checking off, set to FALSE.

Parameter

Description

Advertising