AVer IWH3216 Touch3216 Touch II user manual User Manual

Page 135

Advertising
background image

129

voice.

5. In (4) Sensor, select and click on the sensor number (use  and  to select the sensor) to set the

condition for the system to alarm. If the sensor normal status is high, set the sensor condition to low.

- Continue trigger duration: Set a time period that when sensor has been trigger and stay in the

same status for that period, then the alarm will be sent out.

- Abnormal Event: Enable/disable to set the condition of the event for system to alarm..

System Reboot: when the DVR system reboot without abnormal condition, the system will send

out the alarm message.

Abnormal Reboot: when the DVR system reboot in irregular condition, the system will send out

the alarm message.

Recording is switched off: when the recording has been stopped, the system will send out the

alarm message.

Network is switched off: when the network connection of DVR system is lost, the system will

send out the alarm message.

Hard Disk failed:

when the hard disk can’t work normally, the system will send out the alarm

message.

- POS Keyword: Enable/disable to scan the data from the POS if it matches the keyword.

- Alarm Message: To active with external alarm message by your own program. For the detail

configuration, please contact the local reseller.

- Alarm Button: Enable/disable to active manual alarm function (see also Chapter 2.2#(19)). To define

alarm message of manually alarm trigger. Click alarm button and select the alarm button # and fill in
the description of alarm button.

Advertising