5-5 Objects Usable by DL-EP1

5-26

Connection Manager Object

5

App

end
ix

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

*1

Forward_Open is successful if the size you are trying to open is less than the
size defined in the scan list. If this error occurs, an extended status is added
and the data size of the tag defined in the second extended status is returned.

*2

RPI is set in increments of 500 μs. If a value that cannot be divided by 500 μs is
set, an RPI rounded to the nearest 500 μs is designated.

Forward_

Open

01H

0315H

• Connection Size of the ForwardOpen network connection

parameter is 0.

• Connection Path of ForwardOpen does not include

ConnectionPoint.

• In Connection Path class ID of ForwardOpen, a value other

than 0x04 was set as cyclic or a value other than 02H was

set as Class 3.

• In Class3, a value other than 1 is set as the instance ID of

Connection Path of ForwardOpen.

• There is a setting unique to the product (data segment).
• In cyclic communication, an invalid Connection Point is

designated in the send direction of Connection Path of

ForwardOpen.

• In cyclic communication, a value other than 2 is

designated as the Connection Size network connection

parameter in the send direction of ForwardOpen.

• In cyclic communication, an invalid Connection Point is

designated in the receive direction of Connection Path of

ForwardOpen.

0322H

An error occurred when the DL-EP1 was reinitializing

communication or when it was communicating with a sensor

amplifier.

0323H

An unsupported sensor was connected.

0324H

The connected sensors are in an unmixable combination.

0326H

Too many sensors are connected.

04C2H

A product-unique setting error occurred.

0640H-067FH The appropriate device is not connected or an error occurred

during communication between sensors.

06C0H-06FFH The number of occupied slots is different

0700H-073FH When "Check Model Match" is selected as compatibility

check, ProductCodes do not match.

0740H-077FH When "Check Model Match" is selected as compatibility

check, the major revisions or minor revisions do not match.

0780H-07BFH When "Check Series" is selected as compatibility check, the

series codes do not match.

07C0H-07FFH

When "Check Series" is selected as compatibility check, the

series version of the real machine is lower than the set

series version.

02H

-

The maximum number of connections have already been

used.

04H

-

The attribute ID is already designated.

05H

-

The designated instance ID does not exist.

13H

-

The length of send data is too short.

15H

-

The length of send data is too large.

Others

08H

-

The designated service is not supported.

Name

General

Status

Additional

(Extended)

Status

Description