4 message communication 3-42, Com m uni ca tin g w ith the g t2 s er ies – KEYENCE DL-EP1 User Manual

Page 72

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

3-4 Message Communication

3-42

3

C

om
m

uni

ca

tin

g

w

ith

the

G

T2

S

er

ies

Group4

038EH

(910)

Display

resolution

Indicates the display resolution.

Parameter range: 0 to 3 (initial value: 0)

0: 0.0001

1: 0.001

2: 0.01

3: ___0.1

R/W

DINT

038FH

(911)

Hysteresis

Indicates the hysteresis.

Parameter range: 0.0000 to 199.9999

(Initial value: 0.0030)

R/W

DINT

0390H

(912)

Simultaneous

input

setting

*12

Indicates the simultaneous input setting.

Parameter range: 0 to 1 (initial value: 0)

0: Individual input

1: Simultaneous input

R/W

DINT

0391H

(913)

Special output

setting

*1, *14

Indicates the special output setting.

Parameter range: 0 to 5 (initial value: 0)

0: Not used

1: 5-output

2: Limit output

3: Limit output user setting

4: All GO

5: All limit output

R/W

DINT

0392H

(914)

Limit output

HH position

*1

Indicates the limit output HH position.

Parameter range:

-199.9999 to 199.9999 (initial value: 0.5000)

R/W

DINT

0393H

(915)

Limit output

LL position

*1

Indicates the limit output LL position.

Parameter range:

-199.9999 to 199.9999 (initial value: 0.5000)

R/W

DINT

0394H

(916)

Select preset

data

Indicates the select preset data.

Parameter range: 0 to 1 (initial value: 0)

0: R.V. value

1: P.V. value

R/W

DINT

0395H

(917)

Preset

memory

Indicates the preset memory.

Parameter range: 0 to 1 (initial value: 0)

0: YES

1: NO

R/W

DINT

0396H

(918)

Preset point

Indicates the preset point.

Parameter range: 0 to 1 (initial value: 0)

0: Common to all banks

1: Save for each bank

R/W

DINT

0397H

(919)

Power-saving

function

(ECO)

Indicates the power-saving function (ECO).

Parameter range: 0 to 2 (initial value: 0)

0: OFF

1: HALF

2: ALL

R/W

DINT

0398H

(920)

Jam

detection

function

Indicates the jam detection function.

Parameter range: 0 to 2 (initial value: 0)

0: OFF

1: ON

2: USER

R/W

DINT

0399H

(921)

Jam

detection

position

Indicates the jam detection position.

Parameter range:

-199.9999 to 199.9999 (initial value: 0.5000)

R/W

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising