2-3

2

C

onn
ec

tion

and

C

onf

ig

ur

at

ion

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

2-2

Installation and Connection to Sensor Amplifiers

„

Number of Connectable Sensor Amplifiers

* Up to 11 sensor heads can be connected by adding a head connection board to

the main unit.

This section describes how to mount the DL-EP1 on the DIN rail and to connect it to
sensor amplifiers.
Sensor amplifiers supporting D-bus are connectable. You can connect one sensor to
the DL-EP1 as a main unit and one or more sensors to the main unit as expansion
units. (D-bus is the name of KEYENCE's wiring-saving system for sensor amplifiers.)
If the sensor amplifier is D-bus compatible, different models can be connected
together.

How many and what types of sensor amplifiers can be connected depends on the
sensor amplifiers or units to be connected. Please inquire for details.

„

Mounting the DL-EP1 on the DIN rail

1

Align the claw on the bottom of the DL-EP1 with the DIN rail. While
pushing the amplifier in the direction of arrow (1), press down in the
direction of arrow (2).

2

To remove the DL-EP1, raise the amplifier in the direction of arrow (3)

while pushing the DL-EP1 in the direction of arrow (1).

Name

Amplifier form

Main unit

Expansion

unit

Maximum number of

connectable units

GT-2
Series

DIN rail mount
type

GT2-71(M)(C)N
GT2-71(M)(C)P

GT2-72(M)(C)N
GT2-72(M)(C)P

15
(1 main unit,
14 expansion units)

Panel mount
type

GT2-75N
GT2-75P

GT2-76N
GT2-76P

15
(1 main unit,
14 expansion units)

Large display
type

GT2-100N
GT2-100P

-

1
(1 main unit)*

Mounting and connection to Sensor Amplifiers