background image

3-4 Message Communication

3-23

3

C

om
m

uni

ca

tin

g

w

ith

the

G

T2

S

er

ies

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

(2) Writing data to a sensor amplifier

Message communication writes parameters to the DL-EP1 and the sensor
amplifier connected to the DL-EP1.

"(2) Writing parameters to a sensor amplifier" (Page 3-47)

(3) Issuing operation commands to a sensor amplifier

Message communication issues operation commands such as preset to the DL-

EP1 and the sensor amplifier connected to the DL-EP1.

"(3) Issuing operation commands to a sensor amplifier" (Page 3-48)

(4) Locking sensor amplifier operations

Message communication locks operations by keys on the sensor amplifier
connected to the DL-EP1.

* If a key is locked, message communication cannot switch a bank.

"(4) Locking sensor amplifier operations" (Page 3-49)

Command:
6000

Response

GT2-7∗

jam detection position: 50006000

DL-EP1

Scanner

<Details of command>
Service code: 10H
Class ID: 67H
Instance ID: 01H
Attribute ID: 0399H(921)
Service data: 6000

GT2-7∗

Command

Response

Preset

execution by GT2-7∗

DL-EP1

Scanner

<Details of command>
Service code: 4BH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0301H(769)

GT2-7∗

Command

Response

Changes using the

sensor amplifier keys are locked.

DL-EP1

Scanner

<Details of command>
Service code: 4CH
Class ID: 67H
Instance ID: 00H
Service data: 01H