3 cyclic communication 3-12 – KEYENCE DL-EP1 User Manual

Page 42

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

3-3 Cyclic communication

3-12

3

C

om
m

uni

ca

tin

g

w

ith

the

G

T2

S

er

ies

*1 There is no assigned output in GT2-71MC*.

Current Value 0/Current Value 1

Error ID Number

If "Error Status" in ON, the ID number of the DL-EP1 where the error occurred and

the ID numbers of sensor amplifiers connected to the DL-EP1 are stored (the ID

number of the DL-EP1 is 0). If no error has occurred, 0 is stored. If an error occurs

in multiple IDs, the ID number of the DL-EP1 or sensor amplifier where the highest

priority error occurred is stored.

Error priority:

(1) DL-EP1 error

(2) Sensor amplifier errors (the error with the smallest error code has the

highest priority)

*

* If the same error code occurs in multiple sensor amplifiers, the error

with the smallest ID number has the highest priority.

Error Code

If "Error Status" is ON, the error code is stored. If no error has occurred, 0 is

stored. If an error occurs in multiple IDs, the error code of the DL-EP1 or sensor

amplifier where the highest priority error occurred is stored.

Error priority:

(1) DL-EP1 error

(2) Sensor amplifier errors (the error with the smallest error code has the

highest priority)

*

* If the same error code occurs in multiple sensor amplifiers, the error

with the smallest ID number has the highest priority.

"Error code list" (Page 3-13)

Warning ID

Number

(Unassigned)

Warning Code

(Unassigned)

Current Value n

(n: 0 to 1)

The current value n (n: 0 to 1) of the sensor amplifier is stored. The current value

0 always exists without reference to sensor amplifier models. Whether the

current value 1 exists depends on sensor amplifier models. If the current value

1 does not exist, 0 is stored. The contents displayed in the current value n (n: 0

to 1) depend on the use conditions.

(* The current value 1 does not exist in the GT2 Series.)

"Current Value 0/Current Value 1" (Page 3-12)

Item

Description

Name

Model

Conditions

Function

Current Value 0

Main unit/

expansion unit

When calculation mode is

OFF

Comparator value (P.V.)

When calculation mode is

ON (standard difference)

Comparator value (P.V.)

When calculation mode is

ON (other than standard

difference)

Raw value (R.V.)

When calculation-only mode

is used

Comparator value (P.V.)

Current Value 1

Main unit/

expansion unit

-

(Unassigned)

Advertising