3-4 Message Communication

3-43

3

C

om
m

uni

ca

tin

g

w

ith

the

G

T2

S

er

ies

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

Group4

039AH

(922)

Batch

setting

*15

Indicates the batch setting. (GT2-100* only)

Parameter range: 0 to 1 (initial value: 0)

0: Individual

1: Batch

R/W

DINT

039BH

(923)

Analog

Range

setting

*16

Indicates the analog range setting.

Parameter range: 0 to 1 (initial value: 0)

0: Default

1: Free range setting

R/W

DINT

039CH

(924)

Free range

setting

(Hi)

*16

Indicates the free range setting (Hi).

Parameter range:

-199.9999 to 199.9999 (initial value: 12.0000)

R/W

DINT

039DH

(925)

Free range

setting

(Lo)

*16

Indicates the free range setting (Lo).

Parameter range:

-199.9999 to 199.9999 (initial value: 0.0000)

R/W

DINT

039EH

(926) to

039FH

(927)

Reserved for system

Group5

03A0H

(928)

Group5

Entry count

Indicates the number of items

(number of entries) that can be set in Group 5.

Parameter range: 15

R

DINT

03A1H

(929)

R.V. (base of

calc.) ID1

*4, *17

Indicates the R.V. value of main unit (ID number

1) on which the calculation result was based.

Parameter range:

-199.9999 to 199.9999 (initial value: 0.0000)

R

DINT

03A2H

(930) to

03AEH

(942)

:

03AFH

(943)

R.V. (base of

calc.) ID15

*4, *17

Indicates the R.V. value of expansion unit (ID

number 15) on which the calculation result was

based.

Parameter range:

-199.9999 to 199.9999 (initial value: 0.0000)

R

DINT

03B0H

(944) to

03BFH

(959)

Reserved for system

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising