2 data processing time, Data processing time -3, Data processing time – KEYENCE DL-EP1 User Manual

Page 85

Advertising
background image

4-3

4

Sp
eci
fic

ati

ons

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

4-2

Data Processing Time

This section describes the length of time that lasts from detection by a sensor to data

processing by PLC.

Maximum data processing time = (1) + (2) + (3) + (4)

(1)PLC scan time

(2)RPI (Transmission cycle)

(3)DL-EP1 data communication time

(4)Sensor amplifier response time

(2)RPI is set with the scanner unit. It can be set in 0.5 ms increments between 0.5 ms

and 10000 ms.

(3)DL-EP1 data communication time

The time required for sending outputs and current value data from a sensor

amplifier to the DL-EP1 is as follows:

Sensor amplifier with calculation function OFF, or sensor amplifier with no

calculation function

* For GT2-100 series, add 50 ms to the values above.

Number of connected sensor

amplifiers

Output, judgment value, or

current value

GT2 series*

1

7.8 ms

2

9.8 ms

3

13.8 ms

4

15.8 ms

5

19.8 ms

6

21.8 ms

7

25.8 ms

8

27.8 ms

9

31.8 ms

10

33.8 ms

11

37.8 ms

12

39.8 ms

13

43.8 ms

14

45.8 ms

15

49.8 ms

CPU unit

EtherNet/IP

scanner

DL-EP1

Sensor amplifier

(1)

(2)

(3)

(4)