- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

3-4 Message Communication

3-24

3

C

om
m

uni

ca

tin

g

w

ith

the

G

T2

S

er

ies

(5) Reading the number of decimal places from a sensor amplifier

Message communication reads the number of decimal places of settings read
from the sensor amplifier.

"(5) Reading the number of decimal places in the parameter from a sensor

amplifier" (Page 3-51)

For the GT2 Series, if the current value is 12.53 mm, data is stored as
follows:
Data: 125300
Number of decimal places: 4

Perform calculation from the read data and the number of decimal places.

If message communication writes data to a sensor amplifier, issues an
operation command to the sensor amplifier, or locks sensor amplifier
operations, the sensor amplifier button operations are locked for about 10
seconds. "COM-Lock (

)" is displayed for about 2 seconds during

switching to the locked state or when an attempt is made to operate a
locked button. When button operation is unlocked, "COM-Unlock
(

)" is displayed for about 2 seconds.

Command

Response

<Details of command>
Service code: 4CH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0325H(805)

Reads the number of decimal

places of the GT2-7∗

comparator value (P.V. value).

Reference

12530012.530012.53mm

Number of

decimal places

4 3 2 1

Point