Parameter List

Item

Description

DL-EP1 Error

Status

The error status of the DL-EP1 is output.
„

ON: An error occurred.

„

OFF: No error occurred.

Warning Status

(Unassigned)

Error Status

The error status of the DL-EP1 or the error statuses of all the connected sensor

amplifiers are output.

When ON, a value is stored in "Error ID Number" and "Error Code". When OFF, 0

is stored in "Error ID Number" and "Error Code".
„

ON: An error occurred in the DL-EP1 or in any of the connected sensor

amplifiers.

„

OFF: No error occurred in the DL-EP1 or in the connected sensor amplifiers.

Sensor Error Status

The target ID number bit of the sensor amplifier where the error occurred is

output.
„

ON: An error occurred in the sensor amplifier with the target ID number.

„

OFF: No error occurred in the sensor amplifier with the target ID number.

Sensor Warning

Status

(Unassigned)

Current Value n

Over Range

(n: 0 to 1)

The current value n (n: 0 to 1) of the sensor amplifier with the target ID number

is compared with the measurement upper limit and the comparison result is

output.
„

ON: The current value n (n: 0 to 1) of the sensor amplifier with the target ID

number is greater than the measurement upper limit.

„

OFF: The current value n (n: 0 to 1) of the sensor amplifier with the target ID

number is less than the measurement upper limit.

(* The current value 1 does not exist in the GT2 Series.)

Current Value n

Under Range

(n: 0 to 1)

The current value n (n: 0 to 1) of the sensor amplifier with the target ID number

is compared with the measurement lower limit and the comparison result is

output.
„

ON: The current value of the sensor amplifier with the target ID number is less

than the measurement lower limit.

„

OFF: The current value of the sensor amplifier with the target ID number is

greater than the measurement lower limit.

(* The current value 1 does not exist in the GT2 Series.)

Current Value n

Invalid

(n: 0 to 1)

The status of current value n (n: 0 to 1) of the sensor amplifier with the target ID

number is output.
„

ON: The current value of the sensor amplifier with the target ID number is

invalid.

„

OFF: The current value of the sensor amplifier with the target ID number is

valid (normal).

(* The current value 1 does not exist in the GT2 Series.)

Output n (n: 1 to 5)

The ON/OFF status of output n (n: 1 to 5) of the sensor amplifier with the target

ID number is output.

Output 1: HIGH output

Output 2: LOW output

Output 3: GO output

Output 4: HH output

*1

Output 5: LL output

*1

„

ON: Output n is output.

„

OFF: Output n is not output.

External Input

Response

n (n: 1 to 5)

An external input response is output when the corresponding external input

request n (n: 1 to 5) is made via communication.

The ID number of an unexisting external input is also output.
„

ON: The external input request was made (ON).

„

OFF: The external input request was not made (OFF).

For details, refer to

"Entering an external input to a sensor amplifier"

(Page 3-18).