4 message communication 3-38, Com m uni ca tin g w ith the g t2 s er ies – KEYENCE DL-EP1 User Manual

Page 68

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

3-4 Message Communication

3-38

3

C

om
m

uni

ca

tin

g

w

ith

the

G

T2

S

er

ies

Group2

032AH

(810) to

033FH

(831)

Reserved for system

0340H

(832)

Group2 Entry

count

Indicates the number of items (entries) that can be

set in Group 2.

Parameter range: 20

R

DINT

0341H

(833)

Bank 0 HIGH

setting

Indicates the bank 0 HIGH setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 5.0000)

R/W

DINT

0342H

(834)

Bank 0 LOW

setting

Indicates the bank 0 LOW setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 1.0000)

R/W

DINT

0343H

(835)

Bank 0

preset value

Indicates the bank 0 preset value.

Parameter range:

-199.9999 to 199.9999 (initial value: 0.0000)

R/W

DINT

0344H

(836)

Bank 0 HH

setting

*1

Indicates the bank 0 HH setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 7.0000)

R/W

DINT

0345H

(837)

Bank 0 LL

setting

*1

Indicates the bank 0 LL setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 1.0000)

R/W

DINT

0346H

(838)

Bank 1 HIGH

setting

Indicates the bank 1 HIGH setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 5.0000)

R/W

DINT

0347H

(839)

Bank 1 LOW

setting

Indicates the bank 1 LOW setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 1.0000)

R/W

DINT

0348H

(840)

Bank 1

preset value

Indicates the bank 1 preset value.

Parameter range:

-199.9999 to 199.9999 (initial value: 0.0000)

R/W

DINT

0349H

(841)

Bank 1 HH

setting

*1

Indicates the bank 1 HH setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 7.0000)

R/W

DINT

034AH

(842)

Bank 1 LL

setting

*1

Indicates the bank 1 LL setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 1.0000)

R/W

DINT

034BH

(843)

Bank 2 HIGH

setting

Indicates the bank 2 HIGH setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 5.0000)

R/W

DINT

034CH

(844)

Bank 2 LOW

setting

Indicates the bank 2 LOW setting.

Parameter range:

-199.9999 to 199.9999 (initial value: 1.0000)

R/W

DINT

034DH

(845)

Bank 2

preset value

Indicates the bank 2 preset value.

Parameter range:

-199.9999 to 199.9999 (initial value: 0.0000)

R/W

DINT

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising