KEYENCE DL-EP1 User Manual

Page 122

Advertising
background image

5-5 Objects Usable by DL-EP1

5-34

Ethernet Link Object

5

App

end
ix

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

Reference 2) Control bits list

„

List of general and additional statuses returned to each service

Bit

Name

Description

0

Auto-negotiate

OFF: Auto-negotiation is disabled (communication

setting is fixed at 10 Mbps).

ON: Auto-negotiation is enabled (communication setting

is fixed at 100/10 Mbps auto).

1

ForcedDuplex Mode

OFF (fixed)

2 to 15

Reserved

OFF (fixed)

Error Code

General

Status

Additional

(Extended)

Status

Description

Get_Attributes_All

00H

-

The service has ended normally.

05H

-

The designated instance ID does not exist.

Get_Attribute_Single

00H

-

The service has ended normally.

05H

-

The designated instance ID does not exist.

14H

-

The designated attribute ID does not exist.

Set_Attribute_Single

00H

-

The service has ended normally.

05H

-

The designated instance ID does not exist.

09H

-

The written value is invalid.

0CH

-

The object cannot execute the requested

service in the current state.

0EH

-

The designated attribute ID cannot be written.

13H

-

The length of send data is too short.

14H

-

The designated attribute ID does not exist.

Others

08H

-

The designated service is not supported.

Advertising