3-4 Message Communication

3-49

3

C

om
m

uni

ca

tin

g

w

ith

the

G

T2

S

er

ies

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

• Responses (when successful)

• Responses (when unsuccessful)

For details on the attribute ID, settings, general status, and additional status of each

parameter, refer to

"DL Object (Class ID:67H)" (Page 3-31) and

"Attributes"

(Page 3-33).

(4) Locking sensor amplifier operations

Message communication executes batch key lock for the sensor amplifier connected

to the DL-EP1.
Service code 4CH is used.

The following settings are required to use this object.

• Service Code
• Class ID
• Instance ID
• Attribute ID
• Service Data

• Commands

Attribute ID

Designates the attribute ID to be designated from

"Attribute".

"(3) Issuing operation commands to a

sensor amplifier" "Attribute IDs supported by the

instance service 4BH (operation command)" (Page 3-

48)

0301H(769)

Service Data

There is no service response data.

-

Item

Description

Data Example

General status

A status (00H) is returned that indicates normal

completion of message communication.

00H

Service response data

There is no service response data.

-

Item

Description

Data Example

General status

A general status for the service is returned

08H

Additional status

An additional status is returned.

-

Service response data

There is no service response data.

-

Item

Description

Data Example

Item

Description

Data Example

Service Code

Designates the "batch lock setting (4CH)" (fixed value).

4CH

Class ID

Designates DL Object (67H)(fixed value).

67H

Instance ID

Designates ID number 0 (00H) for issuing a command

to the DL-EP1 (fixed value).

00H