4 message communication 3-36 – KEYENCE DL-EP1 User Manual

Page 66

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

3-4 Message Communication

3-36

3

C

om
m

uni

ca

tin

g

w

ith

the

G

T2

S

er

ies

*1 If the sensor amplifier is GT2-71MC*, there is no assigned output.
*2 This attribute cannot be used in the GT2-100 Series. The initial value of the

effective ID is read irrespective of the effective ID setting.

For details on current value 0 and current value 1, refer to

"Current

Value 0/Current Value 1" (Page 3-12).

00H

B0H

(176)

Sensor

Status Mask

Setting

Set up the condition to determine if the sensor

error or warning is a recoverable DL-EP1 error

(MS LED blinks in red). If mask is selected, MS

LED does not blink in red when a sensor error or

warning occurs.

Parameter range: 0 to 1 (initial value: 0)

0: Not mask

1: Mask

R/W

UINT

B1H

(177)

Sensor

Connected

Number

*2

Indicates the number of connected sensor

amplifiers.

Parameter range: 0 to 15 (initial value: 0)

R

UINT

B2H

(178) to

C7H

(199)

Reserved for system

0300H

(768)

Error Code

(ID number

00)

Indicates the error code of ID number 0.

Parameter range: 0 to 65535 (initial value: 0)

R

UINT

0301H

(769) to

030EH

(782)

:

030FH

(783)

Error Code

(ID number

15)

Indicates the error code of ID number 15.

Parameter range: 0 to 65535 (initial value: 0)

R

UINT

0310H

(784) to

04FFH

(1279)

Reserved for system

Instance

ID

Attribute

ID

Name

Description

Attribute

Data

Type