1 specifications, Specifications -2, Specifications – KEYENCE DL-EP1 User Manual

Page 84: Sp eci fic ati ons

Advertising
background image

4-2

4

Sp
eci
fic

ati

ons

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -

4-1

Specifications

The specifications of the DL-EP1 are as follows:

*1

D-bus is the name of KEYENCE's wiring-saving system for sensor amplifiers.

*2

The number of connectable sensor units varies with the sensor amplifiers to be
connected. (Up to 15 sensor units can be connected to the GT2 series.)

Product name

EtherNet/IP Compatible Network Unit

Model

DL-EP1

Ethernet

specifications

Compliant standards

IEEE802.3 (10BASE-T)

IEEE802.3u (100BASE-TX)

Transmission rate

10Mbps (10BASE-T)

100Mbps (100BASE-TX)

Transmission medium

STP cable or Category 3 or higher UTP cable (10BASE-T)

STP cable or Category 5 or higher UTP cable (100BASE-TX)

Maximum cable length

100 m (Distance between DL-EP1 and Ethernet switch)

Maximum number of

connectable hubs

4 (10BASE-T)

2 (100BASE-TX)

EtherNet/IP

specifications

Compatible functions

Cyclic communication (Implicit messaging)
Message communication (Explicit messaging)

Compatible with UCMM and Class 3

Number of connections

64

RPI (Transmission cycle)

0.5 to 10000 ms (0.5 ms unit)

Tolerable communication

bandwidth for cyclic

communication

6000pps

Conformance test

Compatible with Version A7

Sensor connection

specifications

Connectable sensors

Sensor amplifiers with D-bus support

*1

Number of connectable

sensor units

Up to 15 units

*2

Indicators

Link/activity indicator (LINK/ACT): Green LED

Module status indicator (MS): 2-color (green/red) LED

Network status indicator (NS): 2-color (green/red) LED

Sensor communication indicator (D-bus) 2-color (green/red) LED

Power voltage

Including 20 to 30 VDC ripple (p-p) 10%

(This voltage is supplied from the connected sensor amplifier)

Power consumption

1500 mW or less (at 30 V 50 mA max)

Environmental

resistance

Operating ambient air

temperature

-20 to +55 °C (no freezing)

Operating ambient air

humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 55 Hz compound amplitude 1.5 mm, 2 hours each in X, Y, Z

directions

Pollution degree

2

Materials

Main unit case: Polycarbonate

Weight Approx.

70g

Advertising