(5) Comp threshold button [Compressor Threshold (dB)]

Displays the compression threshold level for each channel by means of
numerical values. If you press this button, a dialog for threshold level
setting is displayed, enabling you to set the level by directly entering a
numerical value. (Setting range: –10 to +20 dB)
The Up and Down buttons located on the right side can also be used to
change the threshold level in 1 dB units.

(6) Comp ratio button [Compressor Ratio]

Displays the compression level for each channel by means of numerical values. If this button is pressed,
setting values can be selected from the pull-down menu. The Up and Down buttons located on the right
side can also be used to change the value.

(7) Comp attack button [Compressor Attack (ms)]

Displays the compression attack time for each channel by means of numerical values. Pressing this button
permits setting values to be selected from the pull-down menu. The Up and Down buttons located on the
right side can also be used to change the value.

(8) Comp release button [Compressor Release (ms)]

Displays the compression release time for each channel by means of numerical values. Pressing button
permits setting values to be selected from the pull-down menu. The Up and Down buttons located on the
right side can also be used to change the value.

(9) Comp gain button [Gain (dB)]

Displays the compression gain for each channel by means of numerical
values. If you press this button, a dialog for compression gain settings
is displayed, enabling you to set the gain by directly entering a
numerical value.
Setting range: –

∞ (–70) to +10 dB

You can also change the gain in 1 dB units with the Up and Down
buttons located on the right side.

Threshold level

Input signal level

Reduction level

Output signal level

L channel input level meter

R channel input level meter

L channel output level meter

R channel output level meter

(4) Input/output level meter

Displays the input/output signal, the reduction (how much the compressor has worked) and the threshold
levels by way of the following bar graph when the D-901 is operating during communications between the
D-901 and the PC.

If Stereo Link function is set to channels, the level meters of both left and right channels are
simultaneously displayed.