17.4. Contact Output Setting Screen

Select [Option

→ External Control... → Contact output] from the menu. The Contact Output setting screen is

then displayed.

(1) Function

Sets the function of the terminal.
The individual terminal pins 1 – 8 are initially set
to the "Preset memory 1 – 8," and other pins all
set to "Break."
• Break

Always at break.

• Make

Always at make.

• Memory

Outputs memory selection status.

• Channel On

Outputs channel ON/OFF status.

• Contact input status

Outputs input contact terminal status.

• Line input

Outputs stereo input selection status (the D-
936R or D-937SP must be mounted).

(2) Parameter

Sets the preset memory number for Memory
selection status output, input terminal number for
Contact input status output, and input number for
Stereo input selection status output.

(3) Control

No item to be set.

(4) Position

Selects the input or output for Channel ON/OFF
status output, and the slot in which the D-936R or
D-937SP is mounted for Stereo input selection
status output.

(5) Channel Contact

Selects the channel used for Channel ON/OFF
status output operations.

Advertising