8.15. Digital Input Module View

(Available only when the D-937SP is used)

Click the "D-937SP" box displayed on the input slot in the Flow View. The Digital Input Module View is then

displayed.

(1)

(2)

(3)

(4)

(1) Channel status indication [Status]

Displays the input signal status of the selected channel.

Display

Input signal status

LOCK

Normal.

UNLOCK

No cable connected or equipment power not
turned on.

Non AUDIO

Not an audio signal.

Non PCM

Not PCM data.

DTS CD

DTS CD.

The indications are shown by black text on white background for the LOCK status, and white text on red
background for the error status.
In error status, the error status indicator lights red on the "D-937SP" box in the Flow View as shown below.

(2) Sampling frequency indication [Fs (Hz)]

Displays the sampling frequency of the selected channel.

(3) Pre-emphasis ON/OFF status [Pre emphasis]

Displays the pre-emphasis ON/OFF status of the selected channel.

(4) D-937SP module input selection (Line selection) [1, 2, 3, 4]

Displays the selected status of the D-937SP module's inputs 1 – 4. The selected input is indicated by the

symbol. Double-clicking the input indication switches the selection status between "selected" and

"unselected."
Note
Unlike the MIX ALL mode of the D-936R, only one input can be selected.